Summer Sale Limited Time 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code = simple75

Pass the DELL EMC DECA-PowerEdge D-PE-OE-01 Questions and answers with Dumpstech

Exam D-PE-OE-01 Premium Access

View all detail and faqs for the D-PE-OE-01 exam

Practice at least 50% of the questions to maximize your chances of passing.
Viewing page 1 out of 2 pages
Viewing questions 1-10 out of questions
Questions # 1:

A PowerEdge server running a virtualization workload shows CPU throttling under load, despite sufficient PSU capacity and no hardware faults. Which configuration is the cause of this issue?

Options:

A.

BIOS System Profile set to Performance per Watt

B.

iDRAC NIC set to shared mode

C.

Hyper-Threading enabled

D.

RAID controller cache set to Write-Through

Questions # 2:

You are replacing a network card in a Dell server. The new card has a firmware version lower than the existing part. The Lifecycle Controller Is set to Allow Version Upgrade only under the Part Firmware Update setting. What will happen to the firmware after replacing the card?

Options:

A.

Forces downgrade of existing firmware

B.

Updates the network card firmware

C.

Prevents all firmware updates

Questions # 3:

A company operates a Dell PowerEdge server configured with a RAID 10 virtual disk that hosts critical databases services. Monitoring tools indicate that the virtual disk usage has reached 95% of total capacity. The server provides 24/7 mission-critical services, so downtime must be minimized or completely avoided. Currently, the server has only one empty drive bay remaining. What should the operations team consider first to safely plan the expansion of the RAID 10 virtual disk?

Options:

A.

Check the RAID controller's capabilities, available drive bays, and whether expansion is supported.

B.

Replace the RAID controller with the latest model to guarantee maximum performance, then add the new disk.

C.

Add the new disk, trigger a rebuild of the RAID, and wait until the rebuild is complete before using the expanded capacity.

D.

Add the new disk and immediately perform Online Capacity Expansion through iDRAC.

Questions # 4:

An administrator wants to ensure continuous visibility into the hardware health of a Dell PowerEdge server and be notified immediately if a component begins to fail. Using iDRAC, what action should be taken to meet these requirements?

Options:

A.

Monitor hardware health only through the operating system tools

B.

Log in to iDRAC only after the operating system reports a failure

C.

Configure iDRAC hardware health monitoring with automated alerting

D.

Disable system alerts to reduce unnecessary notifications

Questions # 5:

A PowerEdge R750 reports “Degraded" status with a question mark next to several components in iDRAC, but all OS-level monitoring tools show no hardware errors. What should be checked first to identify the cause?

Options:

A.

System Event Log (SEL)

B.

BIOS boot mode

C.

Lifecycle Controller firmware version

D.

RAID virtual disk layout

Questions # 6:

A technician In a data center must update the firmware on a server that has no network connectivity. Which two tools must the technician use together to update the BIOS, iDRAC, and lifecycle Controller firmware?

Options:

A.

USB key with Dell Update Package

B.

Virtual console

C.

SMB share

D.

OpenManage Server administrator

Questions # 7:

A PowerEdge server unexpectedly rebooted, and the SEL did not provide enough information to determine the cause. Upon investigation, the engineer noticed that the Last Crash Screen feature was disabled and recommended enabling it. Which primary gap does enabling the Last Crash Screen address?

Options:

A.

The system may lose the final crash state before logs are written.

B.

OS-level crash dump data may be incomplete when writes fail.

C.

Crash during POST may cause firmware messages to be lost.

D.

Sensor activity may not be captured when a crash occurs suddenly.

Questions # 8:

You are managing PowerEdge Servers in different locations across the globe. Your security team instructed you to apply specific settings and firmware on the BIOS to comply with Company policies. You must ensure these applied settings and firmware do not change or have anomalies overtime. How could you achieve this?

Options:

A.

Use DC-HPM

B.

Use Enterprise Key Management

C.

Use BIOS Live Scanning

D.

Use DC-MHS

E.

Use iDRAC Credential Vault

Questions # 9:

You are managing a PowerEdge R570 and iDRAC is not reachable on the Network. You need to collect iDRAC details on the server. Which two tools will allow you to get the iDRAC details?

Options:

A.

Use RACADM to capture inventory and log

B.

Use iSM to capture inventory and log

C.

Use Lifecycle Controller to capture inventory and log

D.

Use OME to capture inventory and log

Questions # 10:

A disk fails in a RAID 5 array on a PowerEdge R760. You replace it, but the rebuild process takes longer than expected. What is a possible cause of this behavior?

Options:

A.

The OS needs updates

B.

The rebuild process slows down the array

C.

The replacement disk is the wrong size

D.

The RAID cache card is disabled

Viewing page 1 out of 2 pages
Viewing questions 1-10 out of questions