Black Friday VIP Hour Limited Time 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code = simple75

Pass the Huawei HCSA-Presales-AI H19-465_V1.0 Questions and answers with Dumpstech

Exam H19-465_V1.0 Premium Access

View all detail and faqs for the H19-465_V1.0 exam

Practice at least 50% of the questions to maximize your chances of passing.
Viewing page 1 out of 2 pages
Viewing questions 1-10 out of questions
Questions # 1:

Which of the following are key technologies for effectively improving cluster performance?

Select all that apply.

Options:

A.

Data Labeling

B.

Collective Communication

C.

Fused Operator

D.

Parallel Acceleration

Questions # 2:

To lower the data center’s energy consumption, the data-center equipment room uses a hybrid cooling approach of “air and liquid.” Which statement about “air” is correct?

Options:

A.

Natural air cooling

B.

Comfortable air conditioning cooling

C.

Precision air conditioner cooling

D.

Electric fan cooling

Questions # 3:

Which of the following statements about the Atlas 800I A2 inference server are accurate?

Select all that apply.

Options:

A.

The overall inference throughput is higher, and the user experience of latency is better.

B.

Recommended for non-latency-sensitive scenarios

C.

8 NPUs per server, full-mesh high-bandwidth interconnection

D.

Supports models of hundreds of billions of parameters and long-sequence inference.

Questions # 4:

The scale of parameters in foundation models generally extends to billions, tens of billions, or even hundreds of billions.

Options:

A.

TRUE

B.

FALSE

Questions # 5:

In the Xinghe Intelligent Campus network, which of the following methods are mainly used to enable AI-powered zero-leakage information technology at the air interface?

Select all that apply.

Options:

A.

Wi-Fi Shield technology

B.

Physical layer scrambling technology

C.

Physical isolation of AP devices

D.

Encrypted data transmission over the air interface

Questions # 6:

The Xinghe Intelligent data center network uses AI-driven network simulation and verification to perform simulation validation before network changes, thereby ensuring zero interruption during change operations.

Options:

Questions # 7:

The NetMaster large model in Huawei’s Xinghe Intelligent Network solution is able to achieve a 100% self-closed loop for resolving faults.

Options:

A.

TRUE

B.

FALSE

Questions # 8:

To lower data-center power consumption, Huawei data centers use a hybrid deployment of air and liquid cooling. The data-center module comprises diesel generator sets, air-cooled PODs, and liquid-cooled PODs.

Options:

A.

TRUE

B.

FALSE

Questions # 9:

How long is typically needed to pre-train a model?

Options:

A.

More than 1 month

B.

3 weeks

C.

2 weeks

D.

1 week

Questions # 10:

What are the primary features of the liquid-cooling solution in new AI equipment-room scenarios?

Select all that apply.

Options:

A.

Improved computing power per unit of electricity consumed

B.

1 week go-live

C.

PUE=1.6

D.

Low Capex investment

Viewing page 1 out of 2 pages
Viewing questions 1-10 out of questions