Questions # 1:

The fire-resistance of a protected mass timber assembly is equivalent to the fire resistance time of the:

Options:

A.

mass timber itself.

B.

noncombustible protection.

C.

mass timber itself plus the finish rating time of the noncombustible protection.

D.

mass timber itself plus the added contribution time attributable to the noncombustible protection.

Questions # 2:

Refer to the exhibit by clicking on the EXHIBIT button above.

Question # 2

In the detail shown, the 2x2 block is intended for what purpose according to AWC Technical Report 10?

Options:

A.

Decorative trim

B.

Provide 1-hour of fire protection for the steel ledger

C.

Resist the passage of air at abutting edges of wood members

D.

Protect the abutting wood edges from char contraction

Questions # 3:

The time, in minutes, contributed to the fire resistance rating by the noncombustible protection of mass timber building elements, components, or assemblies, shall be established through a comparison of assemblies tested using procedures set forth in ASTM Standard:

Options:

A.

E114

B.

E119

C.

E920

D.

D3498

Questions # 4:

Refer to the exhibit by clicking on the EXHIBIT button above.

Question # 4

In the detail shown, what is the required tolerance in inches between the steel beam web and CLT?

Options:

A.

3/16

B.

1/2

C.

2

D.

3

Questions # 5:

Fire-resistance ratings of members and assemblies can be established by all of the following except:

Options:

A.

calculations per IBC Section 722.

B.

fire-resistance testing in accordance with ASTM E84.

C.

fire-resistance designs documented in approved sources.

D.

prescriptive designs of fire-resistance-rated building elements, components or assemblies as prescribed in IBC Section 721.

Questions # 6:

Given: A special inspector notices on a mass timber building set of drawings a 8 in. x 8 in. solid sawn nominal dimension lumber element.

The design team has recommended the solid sawn member be replaced with an SCL element.

What minimum SCL size would be correct per the International Building Code?

Options:

A.

6-3/4 in. x 6-1/4 in.

B.

7 in. x 7-1/2 in.

C.

6-3/4 in. x 8-1/4 in.

D.

8 in. x 8 in.

Questions # 7:

Mass timber is allowed in which of the following International Building Code Construction Types?

Options:

A.

Types I, II, and IV only

B.

Types III and IV only

C.

Types IV and V only

D.

Types I, II, III, IV, and V

Questions # 8:

For Type IV-A construction, noncombustible protection shall provide what fraction of the required fire-resistance rating for building elements?

Options:

A.

1/3

B.

1/2

C.

2/3

D.

3/4

Questions # 9:

Proprietary nails can be used by referencing which ICC-ES Evaluation Report?

Options:

A.

ESR-1002

B.

ESR-1137

C.

ESR-1539

D.

ESR-1722

Questions # 10:

Which of the following best describes the required protection for mass timber hoistway enclosure walls in Type IV-C construction?

Options:

A.

Noncombustible protection of at least 40 minutes fire resistance

B.

No requirement, but walls must achieve the required fire-resistance rating

C.

Noncombustible protection of at least 1/2 in. gypsum board or equivalent

D.

fire-retardant-treated-wood sheathing, 1/2-inch gypsum board, or a noncombustible material

Viewing page 1 out of 3 pages