Questions # 1:

What method is used to verify tightness of accessible bolted electrical connections?

Options:

A.

Compression of the lock-nut

B.

Visual inspection of torque markings

C.

Verification of assembly check sheet

D.

Calibrated torque wrench

Questions # 2:

Which source inspection effort level is MOST appropriate for the highest-risk equipment?

Options:

A.

No source inspection

B.

Final source inspection only

C.

Intermediate source inspection

D.

Resident source inspection

Questions # 3:

The Arc Flash PPE is required for:

Options:

A.

work on control circuits with exposed electrical conductors below 120 VAC.

B.

removal of covers on properly installed wireways, junction boxes, and cable trays.

C.

voltage-testing in ac systems with work on energized conductors.

D.

insulated cable examination with no manipulation of cable.

Questions # 4:

What is the process that aims to find potential defects in a product before it is released for delivery?

Options:

A.

Inspection

B.

Examination

C.

Quality Control

D.

Quality Assurance

Questions # 5:

What document is used for petroleum and chemical industry premium-efficiency, severe-duty, totally enclosed fan-cooled TEFC squirrel cage induction motors up to and including 370 kW 500 hp?

Options:

A.

API 546

B.

IEEE 141

C.

IEEE 841

D.

NFPA 70

Questions # 6:

Which document should identify the inspection activities to be performed by the assigned source inspector and include the applicable acceptance criteria?

Options:

A.

Purchase requisition

B.

Inspection and Test Plan (ITP)

C.

Shipping release form

D.

Supplier observation report

Questions # 7:

According to NEMA ICS 2, a provision for pad locking shall be provided:

Options:

A.

on the door to prevent opening the combination starter door.

B.

on the external operating handle.

C.

on the wireway to prevent opening the wireway on the motor control center.

D.

on the rear door of the low voltage motor control center.

Questions # 8:

Laminations in a motor stator core are used to reduce:

Options:

A.

AC voltage.

B.

frequency.

C.

energy loss.

D.

DC voltage.

Questions # 9:

NEMA rated motor controllers require a minimum range of conductor sizes for a specific size controller. Which of the following conductor sizes is appropriate for a Size 2 controller?

Options:

A.

2/0 AWG -250MCM at 60°C rated cable and 2/0 AWG -350MCM at 75°C rated cable

B.

2-2/0 AWG at 60°C rated cable and 2-4/0 AWG at 75°C rated cable

C.

10-2/0 AWG at 60°C rated cable and 10-4/0 AWG at 75°C rated cable

D.

10-4 AWG at 60°C rated cable and 10-6 AWG at 75°C rated cable

Questions # 10:

What is the purpose of labeling the temperature range on electrical equipment used in a Class I hazardous area?

Options:

A.

To verify the process temperature and the equipment temperature have the same Class I rating

B.

To ensure that the equipment maximum temperature does not exceed the autoignition temperature of the specific gas or vapor to be encountered

C.

To ensure the equipment is compatible with the other Class I devices

D.

To verify the maximum process temperature does not exceed high levels