Spring Sale Limited Time 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code = simple75

Pass the Autodesk Certified Professional RVT_ELEC_01101 Questions and answers with Dumpstech

Exam RVT_ELEC_01101 Premium Access

View all detail and faqs for the RVT_ELEC_01101 exam

Practice at least 50% of the questions to maximize your chances of passing.
Viewing page 2 out of 2 pages
Viewing questions 11-20 out of questions
Questions # 11:

Refer to exhibit.

Question # 11

The exhibit is a lighting fixture family in the Family Editor environment and the light source is selected.

An electrical designer has downloaded a photometric web tile in IES format from a manufacturer's website for use within this lighting fixture family.

Define the light source's Emit Shape and Light Distribution for use with the photometric web (IES) file. (Select two in the answer area.)

Question # 11

Options:

Questions # 12:

Refer to exhibit.

A panelboard has the following properties:

Question # 12

The Circuit Naming Scheme PanelSlolPhase. which defines the value of the Circuit Number parameter, is configured as follows:

Question # 12

In electrical settings. Phase Labels have not been modified from the default "A." "B." and "C-

The Circuit Number lot a single-pole circuit in the panelboard's first breaker position is----------(Enter the correct value into the field)

Options:

Questions # 13:

An electrical designer needs to check for Interferences between conduit in the host model and beams in a linked structure model in the Interference Check dialog, select the items that the designer must select to perform the interference check. (Select two.)

Question # 13

Options:

Questions # 14:

Refer to exhibit.

Question # 14

An electrical designer expects the total connected load on the switchboard to be 4000VA. but Revit Indicates a total connected load of 3606VA. What Is the cause of the discrepancy?

Options:

A.

The connected loads are set to a different voltage than the switchboard.

B.

The Motor demand factor is configured to adjust the connected load.

C.

Load is connected through the switchboard's feed through lugs.

D.

Sum true load and reactive load is selected in Electrical Settings.

Questions # 15:

What should an electrical designer do to associate a lighting device with light fixtures in a model?

Options:

A.

Create a switch system using the light fixtures to define the system and add the switch.

B.

Create an electrical circuit including the light fixtures and switch as one selection.

C.

Create a switch system by selecting a switch and then adding lights

D.

Create an electrical circuit using the light fixtures to define the system and add the switch.

Questions # 16:

An electrical designer is working in a workshared project with a team of people. The electrical designer does not want to see the linked architectural model in any of their views. The rest of the team still needs to see the architectural link.

Which process should the electrical designer use?

Options:

A.

Manage Links > Select architectural link > Click Unload for me

B.

Manage Links > Select architectural link > Click Remove

C.

Manage Links > Select architectural link > Click Unload

D.

Manage Links > Select architectural link > Click Unload For all users

Questions # 17:

Refer to exhibit.

Question # 17

In this linked architectural model, demolished walls are missing The electrical designer teams from the architect that the walls have been placed in a phase that does not exist in the host model.

Which steps should the designer lake to associate the architectural phases to their phases?

Options:

A.

Open Manage Links > Manage Phases

B.

Select the link > Edit Type > Phase Mapping

C.

Select Phases > Graphic Overrides

D.

Open Visibility Graphics > Revit Links > Display Settings

Questions # 18:

Refer to the exhibit.

Question # 18

An electrical designer models a cable tray in a project and decides to check the box (or Use Annot. Scale tor Single Line Fittings and change the Cable Tray Fitting Annotation Size to 1/8" (3 mm).

What is the result?

(The image is presented m Imperial units: 1 In = 25 mm (Metric units rounded].)

Options:

A.

All cable tray fittings in the project are changed per the new settings.

B.

All cable tray fittings in the project change per the new settings when a views detail level is set to Fine.

C.

New cable tray fittings use the new settings in views set to 1/8" (3 mm) scale.

D.

New cable tray fittings use the new settings after the change.

Viewing page 2 out of 2 pages
Viewing questions 11-20 out of questions