Spring Sale Limited Time 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code = simple75

Pass the Huawei HCIP-Storage H13-624_V5.5 Questions and answers with Dumpstech

Exam H13-624_V5.5 Premium Access

View all detail and faqs for the H13-624_V5.5 exam

Practice at least 50% of the questions to maximize your chances of passing.
Viewing page 2 out of 4 pages
Viewing questions 11-20 out of questions
Questions # 11:

An Industry customer purchases several Huawei flash storage devices for service deployment. During an inspection, an engineer finds that some storage components are faulty and need to be removed and replaced. Which of the following statements Is true about the part removal and replacement?

Options:

A.

The interface modules and system subracks of the storage device can be replaced independently.

B.

The CPUs of the storage device cannot be replaced independently, but can be removed independently.

C.

The memory modules and system disks of the storage device can be removed and replaced independently.

D.

The coin batteries of the storage device cannot be replaced or removed.

Questions # 12:

During flash storage initialization, an administrator needs to change the IP address of a management network port. Which statements about the change are false?

Options:

A.

To change the IP address of the management network port on the CLI, log in to the CLI and run the "change system management_ip" command.

B.

The IP addresses of the management and maintenance network ports must be in different network segments; otherwise, there will be a route conflict.

C.

The administrator needs to apply for and activate a license before changing the IP address of the management network port.

D.

To change the IP address of the management network port on the command-line interface (CLI), the IP address of the maintenance terminal and the default IP address of the storage management network port must be in the same network segment if the administrator logs in to the system through a serial port.

Questions # 13:

When demarcating a performance issue of Huawei flash storage, engineer A finds that the latency observed on the compute side is much longer than that on the storage side. This indicates that the issue most possibly occurred on the storage, for example, the disk performance upper limit has been reached.

Options:

A.

TRUE

B.

FALSE

Questions # 14:

Huawei flash storage supports_____. That is, the existing storage system can be used to meet customers' Increasing requirements by continuously adding storage components.

Options:

Questions # 15:

An industry customer has purchased a Huawei OceanStor Pacific 9950 scale-out storage device for service deployment. During an inspection of the device, the location indicator of a main storage disk module is steady yellow. What is the status of the disk module?

Options:

A.

The main storage disk module is being located.

B.

The main storage disk module is running properly.

C.

The main storage disk module is powered off.

D.

The main storage disk module is faulty or about to fail.

Questions # 16:

During routine inspection, an engineer of a bank finds that an interface module of a Huawei flash storage device is faulty. In this case, the engineer can directly remove and insert the interface module without any pre-operations.

Options:

A.

TRUE

B.

FALSE

Questions # 17:

A government customer has purchased several Huawei OceanStor Pacific series storage devices. An engineer wants to install the distributed parallel client (DPC) on the storage devices. The operations before DPC installation have been completed. Now, the engineer needs to add DPC nodes. Which of the following statements are true about adding nodes?

Options:

A.

The engineer can add nodes by batch importing nodes or manually adding nodes. In either mode, authentication is not required.

B.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the management IP address of the node to be added.

C.

If the engineer selects "Manually Add Node" on DeviceManager, the engineer must enter the service IP address of the node to be added.

D.

If the engineer selects "Batch Import Node" on DeviceManager, the engineer must fill in the downloaded template, and upload the template to complete batch import.

Questions # 18:

After a remote replication consistency group is created, if one remote replication task is faulty, other tasks in the consistency group run normally without waiting for the faulty task to recover.

Options:

A.

TRUE

B.

FALSE

Questions # 19:

Which of the following statements are false about the distributed parallel dlent (DPC) of Huawei scale-out storage products?

Options:

A.

If you want to reserve resources for deploying DPC, the available memory of compute nodes must be greater than or equal to 8 GB, and the memory reserved for the operating system must be greater than or equal to 4 GB.

B.

To enable the performance mode of CPUs, you can run the "cpupower frequency-set -g performance" command.

C.

If services running on DPC require higher performance, you can set CPUs to work in performance mode.

D.

DPC and non-uniform memory access (NUMA) are mutually exclusive. Therefore, the NUMA affinity tuning feature cannot be provided in actual scenarios.

Questions # 20:

Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?

Options:

A.

When a switch network is used, the configured rate of the Fibre Channel host port does not match that of the switch.

B.

The optical fiber is poorly connected or faulty.

C.

The optical module rate of host ports does not match that of front-end storage ports.

D.

The IP address of the service network port on the application server is incorrectly set.

Viewing page 2 out of 4 pages
Viewing questions 11-20 out of questions