Questions # 11:

When a critical alarm is generated in a lithium battery cabinet and the buzzer beeps continuously, the status of the indicator on the MDU is

Options:

A.

Blinking yellow fast

B.

Steady yellow

C.

Blinking red fast

D.

Steady red

Questions # 12:

Which of the following conditions will not cause the wizard startup commissioning to fail?

Options:

A.

The condensate pump is stuck.

B.

The indoor fan 2 drive is faulty.

C.

The electronic expansion valve is not opened.

D.

The water leakage rope is not installed.

Questions # 13:

For hourly statistics reports, data of up to how many days can be queried? For monthly statistics reports, data of up to how many years can be queried?

Options:

A.

5

B.

10

C.

20

D.

30

Questions # 14:

The default address of the WAN1 port on the ECC800-Pro is

Options:

A.

192.168.0.10

B.

192.168.248.10

C.

192.168.248.1

D.

192.168.8.10

Questions # 15:

The NetEco northbound interface does not support the SNMP protocol. Only WebService interfaces are supported.

Options:

A.

True

B.

False

Questions # 16:

What are the colors of indicators on the LCD panel of the MDU?

Options:

A.

Yellow

B.

Green

C.

Red

D.

Orange

Questions # 17:

In alarm management, the status can be identified by masking rules.

Options:

A.

Invalid

B.

Standard

C.

Maintenance

D.

Valid

Questions # 18:

Which of the following statements are true about the routine maintenance of a UPS?

Options:

A.

Environment check: Check whether the temperature and humidity of the equipment room meet the recommended environment requirements. Check whether the equipment room is clean and tidy.

B.

UPS status check: Check whether the UPS works in normal mode, whether an alarm is generated, and whether the UPS is in a proper load.

C.

Routine maintenance of vulnerable components: Periodically check the UPS fan operation, whether there is noise, and whether the rotation speed is abnormal.

D.

If there is no alarm on the UPS panel, do not need to check the installation environment, temperature, and humidity onsite.