Questions # 1:

Which of the following is the cabling mode of external power cables in IT scenarios of the FusionDC1000A?

Options:

A.

Bottom cabling

B.

End wall cabling

C.

Top cabling

D.

End door cabling

Questions # 2:

In a data center power distribution architecture, what is the primary function of a Static Transfer Switch (STS) for critical single-cord loads?

Options:

A.

Convert AC power to DC power for IT equipment

B.

Provide fast switching between two independent AC power sources to maintain continuity

C.

Reduce harmonic distortion by filtering non-linear loads

D.

Increase the output frequency from 50 Hz to 60 Hz

Questions # 3:

After installing the FusionCol8000-C (110–440 kW), inject water to preserve the pressure for the chilled water pipes to how many MPa. After 30 minutes, check that no leakage occurs. Preserve the pressure for 24 hours. If the pressure drop is less than 0.01 MPa and no leakage occurs, the pipes do not leak.

Options:

A.

0.8

B.

0.5

C.

1

D.

1.2

Questions # 4:

The frequency of power supply equipment can be 50 Hz, 60 Hz, or 70 Hz.

Options:

A.

True

B.

False

Questions # 5:

Which of the following models is a Huawei in-room chilled water horizontal air supply product?

Options:

A.

NetCol5000-A070U

B.

FusionCol8000-C210H

C.

FusionCol5000-A050H

D.

NetCol8000-C070D

Questions # 6:

Which of the following statements are true about the industry trend of the data center cooling systems?

Options:

A.

Liquid cooling systems are widely used in high-density solutions.

B.

Cloud + AI – data centers enter a new energy-saving era.

C.

Evaporative cooling systems become the main solution for large data centers.

D.

Higher inlet and outlet water temperatures are the trend of large data center cooling.

Questions # 7:

The FusionCol8000-A230 unit uses two systems. Each system uses three compressors connected in parallel and two EEVs.

Options:

A.

True

B.

False

Questions # 8:

Which of the following is not a scenario-based solution for Huawei data center products?

Options:

A.

FusionDC800

B.

FusionDC1000

C.

FusionModule500

D.

FusionModule2000

Questions # 9:

The rated output capability of a single power module for the UPS5000-H is how many kVA.

Options:

A.

50

B.

100

C.

30

D.

60

Questions # 10:

When the outdoor unit is installed at a position higher than the indoor unit, install an oil trap every five to six meters in the vertical direction along the gas pipe to ensure system reliability.

Options:

A.

True

B.

False