Spring Sale Limited Time 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code = simple75

Pass the Pure Storage FAIS FlashArray-Implementation-Specialist Questions and answers with Dumpstech

Exam FlashArray-Implementation-Specialist Premium Access

View all detail and faqs for the FlashArray-Implementation-Specialist exam

Practice at least 50% of the questions to maximize your chances of passing.
Viewing page 3 out of 8 pages
Viewing questions 21-30 out of questions
Questions # 21:

What command can be used to identify interface status?

Options:

A.

purenetwork list

B.

purenetwork list --all

C.

purenetwork list --eth

Questions # 22:

When adding a data pack into a FlashArray chassis or a DFS shelf, the drives show "unrecognized" status when running List. What is the cause of this status on the newly inserted drives?

Options:

A.

There is a hardware fault that needs to be corrected.

B.

The drives exceed the max space supported for the controller model.

C.

The Purity version of the FlashArray/DFS is incompatible with the new drives.

Questions # 23:

An Implementation Engineer runs check start validate-array-health before starting a FlashArray//X70R3 to FlashArray//X70R5 HWNDU and receives code 60 alert indicating an unhealthy NVRAM module in CH0.NVB1. What action Should the Implementation Engineer take to resolve this?

Options:

A.

Disable the unhealthy NVRAM module and proceed With HWNDU after confirming there is no degraded data.

B.

Reseat the unhealthy NVRAM module, and then verify it is in a healthy status prior to proceeding with the HWNDU.

C.

Proceed with the HWNDU, the //X70 model has a four NVRAM configuration so the array still has redundancy.

Questions # 24:

What is the redundancy of the FlashArray//XL PSUs?

Options:

A.

1+1

B.

2+2

C.

3+1

Questions # 25:

A customer has submitted a Pure Engagement Request (PER) / Implementation Workbook (IWB) and the stated array name is "123". What is the issue With this array name?

Options:

A.

Array name must be alphanumeric.

B.

Array name cannot start with a digit.

C.

Array name must be 4 characters or more.

Questions # 26:

During an intra-series upgrade from //XR3 to //XR4, which command should the Implementation Engineer run to verify host connectivity before removing the secondary controller?

Options:

A.

purehost list --hostless

B.

iobalance --sampletime 30

C.

host_connectivity --hosts

Questions # 27:

Which ports are used by default for replication on a FlashArray//XR4?

Options:

A.

ETH2 and ETH3

B.

ETH3 and ETH4

C.

ETH0 and ETH1

Questions # 28:

An Implementation Engineer is installing a FlashArray//XL chassis with two DirectFlash Shelves. What is the minimum rack space required for this installation?

Options:

A.

9U

B.

11U

C.

12U

Questions # 29:

Prior to running the puresetup command, which command should an Installation Engineer run on a new install of a FlashArray//XR4 array?

Options:

A.

pureboot list

B.

cobalt check . py

C.

purehw list

Questions # 30:

Which enablement feature will cause Mirrored Write statistics to appear in the Analysis section of the FlashArray Purity 6.x GUI?

Options:

A.

FA File

B.

ActiveCluster (AC)

C.

ActiveDR

Viewing page 3 out of 8 pages
Viewing questions 21-30 out of questions