Spring Sale Limited Time 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code = simple75

Pass the Cisco CCNP Data Center 300-615 Questions and answers with Dumpstech

Exam 300-615 Premium Access

View all detail and faqs for the 300-615 exam

Practice at least 50% of the questions to maximize your chances of passing.
Viewing page 4 out of 7 pages
Viewing questions 31-40 out of questions
Questions # 31:

Refer to the exhibit.

Question # 31

An engineer configures the server port on a Cisco Nexus 5000 Series Switch. The switch connects to an NPV edge switch port. The server fails to send the FC traffic to the fabric. Which action resolves the issue?

Options:

A.

Enable the NPIV mode on the Cisco Nexus 5000 switch.

B.

Match the VSAN membership on both ends of the connection.

C.

Configure the BB_credit buffer on the uplink port.

D.

Replace the SFP in slot fc2/12.

Questions # 32:

Refer to the exhibit.

Question # 32

The cURL command fails to complete. Which action resolves the problem?

Options:

A.

Remove " .json\ " from the URL.

B.

Include -p " password " in the command.

C.

Add -H " X-Auth-Token " to the command.

D.

Change " .json " to " .xml " at the end of the URL.

Questions # 33:

Question # 33

Refer to the exhibit A Cisco VXLAN must use bidirectional PIM so that

•Spine2 is the active RP for multicast group 225 0 0 0V24

•Loopback 254 is used as a logical interface for PIM configuration

After configuration was applied, Spine1 became the active RP for multicast group 225.0.0.0/24 instead of Spine2. Which action resolves the issue?

Options:

A.

Configure the IP pim ssm range 232.0.0.08 on Spme1

B.

Delete the bidir keyword from ip pim rp address command on Spine1

C.

Change the IP address of Loopback 254 to 10 254 254 254 on Spine2

D.

Modify the subnet mask of Loopback 254 to ' 30 on Spine2

Questions # 34:

Question # 34

Refer to the exhibit. A network engineer is troubleshooting a Cisco Nexus 5000 Series Switch. The interface between the server and the switch is nonoperational and is expected to operate at 10 Gbps. The drain rate of the interface is 3 Mbps. Which action resolves the issue?

Options:

A.

Configure pause error-disable recovery

B.

Enable link level pause on the interface

C.

Reset priority flow counters

D.

Set priority flow control pause

Questions # 35:

An engineer discovers that an NPV/NPIV uplink experiences a heavy load and plans to add more uplinks. Which statement about what occurs when the new uplinks are added is true?

Options:

A.

Only new connections use the new uplinks automatically.

B.

Paths must be defined before new connections can use the new uplinks.

C.

All connections must be reset before the new uplinks can be used.

D.

New and existing connections use the new uplinks automatically.

Questions # 36:

A Cisco Nexus Dashboard consists of a single master node and three worker nodes, and the dashboard is integrated with a Cisco ACI Multi-Site fabric. An engineer notices that the Cisco ACI site is unavailable on the Nexus Dashboard. Which action resolves the issue?

Options:

A.

Export APIC configuration before the site is onboarded.

B.

Replace the master and worker nodes.

C.

Reregister the site in the Nexus Dashboard GUI.

D.

Re-add a different master node to the physical cluster.

Questions # 37:

A mission-critical server is connected to site A. Connectivity to this server is lost from site B because the MAC route is missing in the OTV VDC of the Nexus 7000 in site B due to MAC aging. Which action allows the flooding of the unknown unicast MAC on the Nexus 7000 in the OTV VDC?

Options:

A.

Use route-map to advertise this MAC statically and redistribute with ISIS.

B.

Unknown unicast flooding is not allowed.

C.

Use the otv flood mac < > command to selectively flood traffic for a given MAC.

D.

Use the otv isis bfd < > command to configure BFD protocol.

Questions # 38:

Question # 38

Refer to the exhibit. An engineer discovered a VFC interface in a down state on a Cisco Nexus Switch. Which action resolves the problem?

Options:

A.

Change the cable between the switch and the server

B.

Reset the Cisco Nexus port toward the file server

C.

Update the CNA firmware and driver versions

D.

Modify the fip keepalive message time to 30 seconds

Questions # 39:

Refer to the exhibit.

Question # 39

A network engineer upgrades the firmware of a Cisco Fabric Interconnect from boot flash. During the process, the fabric interconnect reboots and displays the message shown in the exhibit. Which action resolves the issue?

Options:

A.

Remove the service pack and upgrade through the auto-install procedure

B.

Reset the I/O module and install the firmware image from the boot flash

C.

Boot the kickstart image from boot flash and load the system image

D.

Reload the switch and boot the kickstart image from the TFTP server

Questions # 40:

An upgrade of protected RPMs from the Bash shell did not take effect. Which action is required for the changes to take effect?

Options:

A.

Restart the Bash shell.

B.

Reload the switch.

C.

Upgrade the RPMs from the Guest shell.

D.

Disable and reenable the Bash feature.

Viewing page 4 out of 7 pages
Viewing questions 31-40 out of questions